Imada Cap Torque Tester (DTXA/DTXS Series)
Specifications
Details
Imada Screw cap torque tester (torque gauge) DTXS series is standard type offering highly repeatable torque measurements with 50N-cm to 10N-m(1000N-cm) capacity. by MSP Metrology (M) Sdn Bhd from Imada Japan
Features
Standard Type Screw Cap Torque Tester (Torque Gauge)
DTXA/DTXS Series
Screw cap torque tester (torque gauge) DTXS series is standard type offering highly repeatable torque measurements with 50N-cm to 10N-m(1000N-cm) capacity. It is ideal for measuring opening/closing torque of various samples such as bottles. It comes with data logging software for easy data management.
Feature 1: Saves data to the internal memory
Saves data to the internal memory. (Max.1000 data)
Enables to print out the all saved data by using RS232C printer
Feature 2: High repeatability by high speed sampling
The high speed data sampling rate (2000 data / sec) captures momentary force and digitizes it.
It captures the right max value and enhances repeatability of repeat test.
Feature 3: Enables to measure various samples by various attachments
Changeable pins, tables and attachments. The users can choose the most suitable combination for their sample
Feature 4: Useful functions improving work efficiency
Organic Electroluminescence Display
The display is visually clear as the user can see it from the side or in a dark place.
Various Display
Time display
Easy and certain data managements
Bar graph
For prevention of breaking the sensor(over load). (*1)
Captures Data to PC by included software
Display Force value/Date and time/ OK/NG judgment by connecting PC via USB
Stable Body Fixation
The body can be fixed on a desk with the carry handle holes. It supports testing stable.
Standard Features
- High sampling rate (2000Hz) for accurate results, capturing small changes and accurate peak values by following rapid changes of torque
- Easy data management using supplied software Force Logger via USB connection to PC
- Reduces risk of misreading values with easy-to-read high luminance organic EL display
- Handles a wide range of samples with various optional tables and attachments
- Optional software Force Recorder Light/Standard available for real-time graphing of torque vs. time at 2000 data/sec on PC, visualizing small changes of torque for detailed analysis of results
Specifications
Model | DTXS | DTXA |
Outline | Standard model with various functions | Advanced model with additional functions of DTXS series. Such as input/output angles and saving to USB flash drive etc. |
Accuracy | ±0.5%F.S.±1digit | |
Unit of measurement | N-m, N-cm, kgf-m, kgf-cm, lbf-in, ozf-in (Unit switching is possible.)(*1) | |
Display | 4-digit | |
Display update | 16 times /sec | |
Sampling rate | Maximum 2000 data/ sec(*2) | |
Battery | 8 hours (2 hours full charge)(*3) | |
Safe overload rating | Approx. 200% | |
Operating Environment | Temperature: 0 – 40 degree Celsius Humidity: 20 -80%RH | |
Function | Customized display(header and footer) / Peak hold(Clockwise and Counterclockwise)/ Internal memory(1000 point data)) / Comparator (OK or NG judgment)/ Reversible display/ Sign inversion/ Zero clear timer/ +NG alarm/ Off timer(Auto power off)/ Dumping/ Time display/ setting lock |
|
– | 1st2nd peak/ Angle detection at torque peak value(*4) / Angle zero reset at selected torque(*4) |
|
Output | USB, RS232C, Mitutoyo digimatic (*5), 2 VDC analog output (D/A), Comparator 3 steps (-NG/OK/+NG), Overload alarm |
|
– | Sub comparator 2 steps (output of large or small judgment), USB flash drive, Angle(displacement) |
|
Overload warning | Approx.110%F.S. (Warning message and alarm) | |
External connecting switch |
SEND (a point of contact holding), Zero reset, Peak ON/OFF setting | |
Weight | Approx. 3.0kg (No table model), Approx. 4.5kg (Included standard table and pins) | |
Dimensions | See [Dimensions] | |
Accessory | AC adapter, Inspection certificate, CD driver (including simple software for data logging),USB cable, Carrying case, L wrench |
|
– | USB flash drive adapter(*6) | |
Approved standard | JIS S 0022 (2001) Guidelines for all people including elderly and people with disabilities — Packaging and receptacles — Test methods for opening “6.3 Screw top receptacle” |
*1 These are the specifications for International model. Please note that this unit is different from Japanese domestic model.
*2 Up to 100 data/sec. is saved in USB memory (selectable among 1, 50, and 100 /sec)
*3 The battery is more consumed when connected to USB flash drive or a displacement scale.
*4 Angle(displacement) scale is necessary to valid this function.
*5 Not always available for Mitutoyo digimatic products.
*6 USB flash drive is not included.
DTXS Japan Model (US Model) | DTXA (Japan Model only) | Range | Display | Resolution |
DTXS-0.5N-Z (*1) (*2) (DTXS-4-Z) | DTXA-0.5N-Z (*1) (*2) | 0.5 N-m (50N-cm) | 50.00N-cm | 0.01N-cm |
DTXS-2N (DTXS-15) | DTXA-2N | 2 N-m (200N-cm) | 2.000N-m (200.0N-cm) | 0.001N-m (0.1N-cm) |
DTXS-5N (DTXS-40) | DTXA-5N | 5 N-m (500N-cm) | 5.000N-m (500.0N-cm) | 0.001N-m (0.1N-cm) |
DTXS-10N (DTXS-85) | DTXA-10N | 10N-m (1000N-cm) | 10.00N-m (1000N-cm) | 0.01N-m (1N-cm) |
DTXS-2N-Z (*1) (DTXS-15-Z (*1)) | DTXA-2N-Z (*1) | 2 N-m (200N-cm) | 2.000N-m (200.0N-cm) | 0.001N-m (0.1N-cm) |
DTXS-5N-Z (*1) (DTXS-40-Z (*1)) | DTXA-5N-Z (*1) | 5 N-m (500N-cm) | 5.000N-m (500.0N-cm) | 0.001N-m (0.1N-cm) |
DTXS-10N-Z (*1) (DTXS-85-Z (*1)) | DTXA-10N-Z (*1) | 10N-m (1000N-cm) | 10.00N-m (1000N-cm) | 0.01N-m (1N-cm) |