Accretech Coordinate Measuring Machine (XYZAX AXCEL Series)

Accretech Coordinate Measuring Machine (XYZAX AXCEL Series)


Specifications
Details

With the point measurement models of the XYZAX AXCEL series, you can select from among various specifications based on your specific needs by MSP Metrology (M) Sdn Bhd from Accretech Japan.

 

Features

Class Highest Level Accuracy

Maximum permissible length measurement error E0, MPE:1.8 + 3L/1000 μm*. A newly developed highly rigid bridge delivers the highest level accuracy in class

 


 

Stunning Speed With Newly Developed Drive Mechanism

Amazing speed is achieved by review of the drive mechanism. A maximum drive speed of 700 mm/sec and maximum acceleration of 2300 mm/sec²

 


 

Enhanced Resistance To Environment

This structure prevents deformation of the guide and carriage due to temperature changes, increasing resistance to environment. Temperature to guarantee accuracy: 15 to 30°C.

 


 

Equipped With 2-Axis Rotating Head

By combining 2-Axis rotating head RDS with scanning probe VAST XXT, XYZAX AXCEL can perform high accuracy oscillating scanning measurement at many different angles.

 


 

Temperature Range For Guaranteed Accuracy / X-Axis Guide Cover

If you select 16 – 26°C as the temperature range for guaranteed accuracy for 9/15/6 or smaller size, you can choose not to use the X-axis guide cover.

 


 

Base Cover

You can also select whether or not to use the base cover intended to cover the lower part of the machine (when the size of machine is Z600 or smaller and the optional air anti-vibration unit is not used). Not using the base cover is effective when you want to keep the initial cost as low as possible.

 


 

Probe Composition With Renishaw PH Head

The probe composition of XYZAX AXCEL PH can be selected according to whether the measurement position is to be changed automatically or manually, as well as your specific needs such as the use of modules that differ in the stylus length, measurement force, etc.



Motorized Indexing Probe Head – PH10T PLUS

  • Horizontal surface rotation angle 180°
  • Vertical surface rotation angle 0 to ±105°
  • Probe automatically rotates to conduct measurement
 

Manual Positioning Probe Head – PH1 + TP2

  • Horizontal surface rotation angle 360°
  • Vertical surface rotation angle ±115°
  • Measurement position changed easily using accompanying wrench

 


 

Automatic Geometric Element Recognition

Our own measuring method and recognition algorithms (patented in Japan and overseas) enable automatic recognition of geometric forms by the direct measurement (probing) of a workpiece. This dramatically reduces procedures to input measuring items.

 


 

Automatic Coordinate System Recognition

Measured geometric elements and items required for coordinate system settings (spatial compensation, rotational compensation, origin) are determined automatically and these settings are configured.

 


 

Automatic Generation Of Measuring Path

The measuring path is generated automatically in accordance with safety plane, supplementary safety plane, number of measuring points, and probing return distance. Measuring path points and probing points can be specified arbitrarily within and between measuring elements, which allows the operator to create the most appropriate measuring path

 


 

On-Screen Probe Angle Simulator (For Articulating Probe Head)

The on-screen probe angle simulator provides a screen image of the probe positioned at the input rotation angle and the inclination angle, so the operator can confirm that the desired result has been attained.

 


 

Full Specifications

Type XYZAX AXCEL RDS
 7/5/5  7/7/5 9/6/2006 9/10/2006 9/15/6 10/10/2006 10/12/2006 10/15/6 10/10/2008 10/12/2008 10/15/8
Measuring Range X-axis (mm) 650 850 1000 1000
Y-axis (mm) 500 700 600 1000 1500 1000 1200 1500 1000 1200 1500
Z-axis (mm) 480 600 800
Length Measuring Method Linear Scale System
Minimum Unit (µm) 0.01
Measurement Accuracy RDS-C5 + VAST XXT

Max. Permissible Error of Length Measurement

E0, MPE (µm)

1.8 + 3L/1000 (18 ~ 22°C)

1.8 + 4L/1000 (16 ~ 26°C)

1.8 + 5L/1000 (15 ~ 30°C)

Max. Permissible Error of Length Measurement

E150, MPE (µm)

2.3 + 3L/1000 (18 ~ 22°C)

2.3 + 4L/1000 (18 ~ 22°C)

2.3 + 5L/1000 (18 ~ 22°C)

Max. Permissible Limit of the Repeatability Range, R0, MPL (µm) 1.3
Max. Permissible Single-Stylus Form PFTU, MPE (µm) 1.8
Max. Permissible Error for Scanning Probe MPETHP, (µm) 2.9 (T = 75s)
Guidance System for each Axis Air Bearings
Table Material Gabbro
Usable Width (X) (mm) 950 1050 1200 1270
Usable Depth (Y) (mm) 1400 1600 1500 1900 2400 1900 2100 2400 2000 2200 2500
Flatness JIS Class 1
Clamping Screw for Workpiece M10 Threaded Hole
Workpiece Measured Max. Height (mm) 670 790 1000
Max. Weight (kg) 600 800 800 1000 1500 1000 1200 1500 1000 1200 1500
Drive Speed Max. Acceleration (mm/s²) 2300
Variable Speed Range (mm/sec) Auto Measurement Mode 0.01 ~ 700 (Stepless Control)
Measuring Speed (mm/sec) Joystick and Manual Mode (Automatic Measurement): 0 to 5
Outer Diameter Dimensions Width (mm) 1462 1716 1866 1930
Depth (mm) 1450 1650 1550 1950 2450 1950 2150 2450 2050 2250 2550
Height (mm) 2339 2578 3015
Body Weight (kg) 1610 1800 2100 2550 3150 2850 3100 3450 3800 4100 4600
Machine Height at Transport (mm) 2080 2220 2450
 
Type XYZAX AXCEL RDS
12/15/10 12/20/10 12/25/10
Measuring Range X-axis (mm) 1200
Y-axis (mm) 1500 2000 2500
Z-axis (mm) 1000
Length Measuring Method Linear Scale System
Minimum Unit (µm) 0.01
Measurement Accuracy RDS-C5 + VAST XXT

Max. Permissible Error of Length Measurement

E0, MPE (µm)

 2.2 + 3L/1000 (18 ~ 22°C)

2.2 + 4L/1000 (16 ~ 26°C)

2.2 + 5L/1000 (15 ~ 30°C)

Max. Permissible Error of Length Measurement

E150, MPE (µm)

2.7 + 3L/1000 (18 ~ 22°C)

2.7 + 4L/1000 (18 ~ 22°C)

2.7 + 5L/1000 (18 ~ 22°C)

Max. Permissible Limit of the Repeatability Range, R0, MPL (µm) 2.2
Max. Permissible Single-Stylus Form PFTU, MPE (µm) 3.5
Max. Permissible Error for Scanning Probe MPETHP, (µm) 3.8 (T = 75s)
Guidance System for each Axis Air Bearings
Table Material Gabbro
Usable Width (X) (mm) 1470
Usable Depth (Y) (mm)  2500 3100 3600
Flatness JIS Class 1
Clamping Screw for Workpiece M10 Threaded Hole
Workpiece Measured Max. Height (mm) 1200
Max. Weight (kg)  1500 1000
Drive Speed Max. Acceleration (mm/s²) 2300
Variable Speed Range (mm/sec) Auto Measurement Mode 0.01 ~ 700 (Stepless Control)
Measuring Speed (mm/sec) Joystick and Manual Mode (Automatic Measurement): 0 to 5
Outer Diameter Dimensions Width (mm) 2180
Depth (mm) 2550 3150 3650
Height (mm) 3415
Body Weight (kg) 5200 6300 7600
Machine Height at Transport (mm) 2750
 
Type XYZAX AXCEL PH
 7/5/5  7/7/5 9/6/2006 9/10/2006 9/15/6 10/10/2006 10/12/2006 10/15/6
Measuring Range X-axis (mm) 650 850 1000
Y-axis (mm) 500 700 600 1000 1500 1000 1200 1500
Z-axis (mm) 480 600
Length Measuring Method Linear Scale System
Minimum Unit (µm) 0.01
Measurement Accuracy PH10T PLUS + TP200

Max. Permissible Error of Length Measurement

E0, MPE (µm)

1.8 + 3L/1000 (18 ~ 22°C)

1.8 + 4L/1000 (16 ~ 26°C)

1.8 + 5L/1000 (15 ~ 30°C)

Max. Permissible Error of Length Measurement

E150, MPE (µm)

2.3 + 3L/1000 (18 ~ 22°C)

2.3 + 4L/1000 (18 ~ 22°C)

2.3 + 5L/1000 (18 ~ 22°C)

Max. Permissible Limit of the Repeatability Range, R0, MPL (µm) 1.5
Max. Permissible Single-Stylus Form PFTU, MPE (µm) 2
Guidance System for each Axis Air Bearings
Table Material Gabbro
Usable Width (X) (mm) 950 1050 1200
Usable Depth (Y) (mm) 1400 1600 1500 1900 2400 1900 2100 2400
Height from Floor (mm) 600
Flatness JIS Class 1
Clamping Screw for Workpiece M10 Threaded Hole
Workpiece Measured Max. Height (mm) 670 790
Max. Weight (kg) 600 800 800 1000 1500 1000 1200 1500
Drive Speed Max. Acceleration (mm/s²) 2300
Variable Speed Range (mm/sec) Auto Measurement Mode 0.01 ~ 700 (Stepless Control)
Measuring Speed (mm/sec) Joystick and Manual Mode (Automatic Measurement): 0 to 5
Outer Diameter Dimensions Width (mm) 1462 1716 1866
Depth (mm) 1450 1650 1550 1950 2450 1950 2150 2450
Height (mm) 2339 2578
Body Weight (kg) 1610 1800 2100 2550 3150 2850 3100 3450
Machine Height at Transport (mm) 2080 2220
 
Type XYZAX AXCEL PH
10/10/2008 10/12/2008 10/15/8 12/15/10 12/20/10 12/25/10
Measuring Range X-axis (mm) 1000 1200
Y-axis (mm) 1000 1200 1500 1500 2000 2500
Z-axis (mm) 800 1000
Length Measuring Method Linear Scale System
Minimum Unit (µm) 0.01
Measurement Accuracy PH10T PLUS + TP200

Max. Permissible Error of Length Measurement

E0, MPE (µm)

1.8 + 3L/1000 (18 ~ 22°C)

1.8 + 4L/1000 (16 ~ 26°C)

1.8 + 5L/1000 (15 ~ 30°C)

 2.4 + 3L/1000 (18 ~ 22°C)

2.4 + 4L/1000 (16 ~ 26°C)

2.4 + 5L/1000 (15 ~ 30°C)

Max. Permissible Error of Length Measurement

E150, MPE (µm)

2.3 + 3L/1000 (18 ~ 22°C)

2.3 + 4L/1000 (18 ~ 22°C)

2.3 + 5L/1000 (18 ~ 22°C)

2.9 + 3L/1000 (18 ~ 22°C)

2.9 + 4L/1000 (18 ~ 22°C)

2.9 + 5L/1000 (18 ~ 22°C)

Max. Permissible Limit of the Repeatability Range, R0, MPL (µm) 1.8 2.4
Max. Permissible Single-Stylus Form PFTU, MPE (µm) 2.4 3
Guidance System for each Axis Air Bearings
Table Material Gabbro
Usable Width (X) (mm) 1270 1470
Usable Depth (Y) (mm) 2000 2200 2500  2500 3100 3600
Height from Floor (mm) 630
Flatness JIS Class 1
Clamping Screw for Workpiece M10 Threaded Hole
Workpiece Measured Max. Height (mm) 1000 1200
Max. Weight (kg) 1000 1200 1500  1500 1000
Drive Speed Max. Acceleration (mm/s²) 2300
Variable Speed Range (mm/sec) Auto Measurement Mode 0.01 ~ 700 (Stepless Control)
Measuring Speed (mm/sec) Joystick and Manual Mode (Automatic Measurement): 0 to 5
Outer Diameter Dimensions Width (mm) 1930 2180
Depth (mm) 2050 2250 2550 2550 3150 3650
Height (mm) 3015 3415
Body Weight (kg) 3800 4100 4600 5200 6300 7600
Machine Height at Transport (mm) 2450 2750
 

View more about Accretech Coordinate Measuring Machine (XYZAX AXCEL Series) on main site